Designed for demanding process environments, the Rosemount 140 contacting conductivity sensor supports safe in process maintenance while delivering stable, repeatable conductivity measurements that reduce uncertainty and support confident process control in applications up to 200 °C and 100 psig.
Rosemount™ 140 Retractable Conductivity Sensor
Rosemount™ 140 Retractable Conductivity Sensor
Specs
Design
Cell constants: 0.2 and 1.0 / cm (nominal, to within ±5 %)
Vacuum: At 1.6 in. Hg (5.2 kPa) air leakage is less than 0.005 SCFM (0.00014 m3/min)
Vacuum: At 1.6 in. Hg (5.2 kPa) air leakage is less than 0.005 SCFM (0.00014 m3/min)
Materials of Construction
Wetted Materials:
Electrodes & Body: 316 stainless steel
Insulator: PEEK
O-Rings: Viton™
Electrodes & Body: 316 stainless steel
Insulator: PEEK
O-Rings: Viton™
Maximum Pressure
100 psig (791 kPa [abs])
Temperature Range
Standard: 32 °F to 302 °F (0 °C to 150 °C) maximum
High Temperature: 32 °F to 392 °F (0 °C to 200 °C) maximum
High Temperature: 32 °F to 392 °F (0 °C to 200 °C) maximum
Resources
-
Brochures
-
Data Sheets & Bulletins
-
Data Sheets & Bulletins
-
Data Sheets & Bulletins
-
Drawings & Schematics
-
Manuals & Guides
-
Manuals & Guides
Features
- Retractable design allows conductivity sensor to be removed from a pipe or vessel without shutting down the process
- All installation hardware included
- Available with 0.2 and 1.0/cm cell constants
Our website uses cookies. By continuing to browse our site you are agreeing to our Cookie Policy.