Rosemount™ 1500XA Process Gas Chromatograph
The Rosemount 1500XA process gas chromatograph combines the proven analytical components of Emerson's field-mounted gas chromatographs with the larger oven capacity of a traditional air-bath oven design.
This modular and scalable analyzer provides unmatched flexility and reliability within a single analyzer and can be configured for various process gas applications.
Rosemount™ 1500XA Process Gas Chromatograph
Specs
Ports
Serial Communication Ports: Three termination blocks,configurable as RS-232, RS-422 or RS-485 and one D-sub(9-pin) port for PC connection
Input
Analog Inputs: Two standard inputs filtered with transient
Digital Inputs: Five inputs, user assignable, optically isolated,rated to 30 VDC @ 0.5 A
Digital Inputs: Five inputs, user assignable, optically isolated,rated to 30 VDC @ 0.5 A
Output
Analog Outputs: Six isolated outputs, 4–20 mA
Digital Outputs: Five user-assignable outputs, Form C andelectro-mechanically isolated, 24V DC
Digital Outputs: Five user-assignable outputs, Form C andelectro-mechanically isolated, 24V DC
Mounting
Wall-mount (standard); free-standing (optional)
Dimensions
127 cm H x 102 cm W x 61 cm D (50 H x 40 W x 24 D)
Certifications/Approvals
Class 1 Div. 2, Groups B, C, D with Z-Purge
Weight
Approximately 68 kg. (150 lbs.)
Resources
- All
- Certificates & Approvals
- Data Sheets & Bulletins
- Drawings & Schematics
- Manuals & Guides
- News & Articles
- Training & Demonstrations
-
Certificates & Approvals
-
Certificates & Approvals
-
Data Sheets & Bulletins
-
Data Sheets & Bulletins
-
Data Sheets & Bulletins
-
Drawings & Schematics
-
Drawings & Schematics
-
Manuals & Guides
-
Manuals & Guides
-
Manuals & Guides
-
Manuals & Guides
-
Training & Demonstrations
Features
- Traditional air-bath oven design for maximum application flexibility
- Dual Ethernet communications for connection to DCS systems and maintenance wide area networks using industry standard protocols
- New XA valves, based on the reliable design of our line of superior 6-port chromatograph diaphragm valves.
- Oven capacity for up to eight chromatograph valves and four detectors, up to two of which can be flame detectors
- Choice of thermal conductivity flame ionization, and flame photometric detectors
- Thermal conductivtity detector (TCD) sensitive down to very low parts-per-million levels
- Storage of up to 2,500 chromatograms, including sample calibration and validation streams
- 2 clocks allow up to 2 applications with different analysis cycle times to run simultaneously
- Optional inter-column thermal conductivity (ITC) detectors
- Parallel chromatography to break down complex analysis into simpler analysis trains to improve cycle times and ease of use